Categories
CAN Termination Resistance Software Toggle
Currently supported model and serial number
H-Flow
All version
DLVR Airspeed Sensor
19012001***; 19013001***; 19014001*** and later
PM08-CAN
15028001***; 15029001***; 15030001*** and later
DroneCAN M9N
12032002***
DroneCAN H-RTK F9P Helical
12037003***
DroneCAN RM3100
18088002***; 18089002***
H-RTK ZED-F9P Rover
12059002***
Ardupilot (Mission Planner) setup guide
- Connect the DroneCAN peripheral to the CAN port on the flight controller
After establishing the connection to the flight controller on MissionPlanner, head to Setup->Optional Hardware->DroneCAN/UAVCAN. Click MAVlink-CAN1 if connected to the CAN1 port and MAVlink-CAN2 for the CAN2 port to scan CAN devices.
Find the appropriate device (Holybro products have HolybroG4 in the name), click menu->Parameters:

Find the CAN_TERMINATE command and you will see the value defaults to 0. Set CAN_TERMINATE to 1 to enable 120惟 termination resistance, and 0 to disable it

- Click Write Params to save the configuration
PX4 (QGroundControl) setup guide
- Make sure the parameters are set accordingly so the firmware can detect the CAN device
Navigate to Vehicle Setup->Parameters and click Standard to hide flight controller parameters:

If your CAN device is successfully detected, you will see a section labeled Components with numbers following it:

Expand the Component section, navigate to the CAN tab, and change the CAN_TERMINATE value to enable or disable termination resistance (120惟). Set to 1 to enable and 0 to disable.